Negotiable
The date of payment from buyers deliver within days
Zhejiang
Long-term effective
2020-03-29 04:20
263
Company Profile
Ningbo Jiangbei Watermeter FactoryBy certification [File Integrity]
Contact:jbshuibiao(Mr.)
Email:
Telephone:
Phone:
Area:Zhejiang
Address:Zhejiang
Website:http://www.ningbowatermeter.com/ http://jbshuibiao.rjhefw.com/
Product Description
This series of vertical water meters can be used to measure the total amount of cold (hot) drinking water consumed by pipes in a home or residential building.We have achieved success in the market by manufacturing and exporting a range of superior water meters, water flow meters and hot water meters.
• Wet dial, dry dial or liquid seal available
• Multiple jets
• The measurement accuracy of the Vertical Water Meter is in accordance with ISO 4064 Class B
• This water meter can be installed in a vertical pipe, suitable for branching at home
• Cold water meter or hot water meter to choose from
Application
The Vertical Water Meter is designed to measure cold (hot) potable water in residential settings
Standards
Complies with: ISO 4064(equivalent to GB/T778-2007),MID14154
Product Features
● Vertical installation
● Multi-jet
● C-type, E-type (dry or wet)and F-type (liquid-filled)register options
● Starting flow≤2L/h
● Available for high-sensitive meters.
Flow Technical data
mm |
Q3/Q1 |
Q4 |
Q3 |
Q2 |
Q1 |
Min |
Max |
m³/h |
L/h |
m³ |
|||||
15 |
80 |
3.125 |
2.5 |
50 |
31.25 |
0.00005 |
99999 |
100 |
40 |
25 |
|||||
20 |
80 |
5.0 |
4.0 |
80 |
50 |
0.00005 |
99999 |
100 |
64 |
40 |
|||||
25 |
80 |
7.875 |
6.3 |
126 |
78.75 |
0.00005 |
99999 |
100 |
100.8 |
63 |
Maximum Permissible error
Accuracy between Q1 and Q2±5%
Accuracy between Q2 and Q4±2%(±3%for hot water)
Dimensions and weight
TYPE |
mm |
Length |
Width |
Height |
Connecting Thread |
Weight |
mm |
D |
kg |
||||
LXSL-15 |
15 |
144 |
98 |
100 |
G¾B |
1.6 |
LXSL- 20 |
20 |
152 |
98 |
100 |
G1 B |
1.8 |
LXSL- 25 |
25 |
164 |
104 |
105 |
G1¼B |
2.4 |
WORKING CONDITION
Working temperature for cold water meter: +0.1℃~+50℃
Working temperature for hot water meter: +0.1℃~+90℃
Head loss△P63
Working pressure≤1. 0Mpa
http://www.ningbowatermeter.com/